The KL1312 digital input terminal acquires the binary 24 V DC control signals from the process level and transmits them, in an electrically isolated form, to the higher-level automation unit. The Bus Terminal has two channels, whose signal state is displayed by light emitting diodes.
The KL1314 digital input terminal acquires the binary 24 V DC control signals from the process level and transmits them, in an electrically isolated form, to the higher-level automation unit. The Bus Terminal has four channels, whose signal state is displayed by light emitting diodes.
The KL3112 analog input terminal handles signals in the range from 0 to 20 mA. The current is digitized to a resolution of 16 bits (the default is 15 bits), and is transmitted, in an electrically isolated form, to the higher-level automation device.
The KL3122 analog input terminal handles signals in the range from 4 to 20 mA. The current is digitized to a resolution of 16 bits (the default is 15 bits), and is transmitted, in an electrically isolated form, to the higher-level automation device.
The KL3132 analog input terminal processes signals in the range of -10 to +10 V. The voltage is digitized to a resolution of 16 bits and is transmitted, electrically isolated, to the higher-level automation device.
he KL3142 analog input terminal handles signals in the range between 0 and 20 mA. The current is digitized to a resolution of 16 bits, and is transmitted, in an electrically isolated form, to the higher-level automation device.
The KL3152 analog input terminal handles signals in the range between 4 and 20 mA. The current is digitized to a resolution of 16 bits, and is transmitted, in an electrically isolated form, to the higher-level automation device.
The KL3162 analog input terminal processes signals in the range of 0 to +10 V. The voltage is digitized to a resolution of 16 bits and is transmitted, electrically isolated, to the higher-level automation device.
The KL3172 analog input terminal processes signals in the range of 0 to 2 V. The voltage is digitized to a resolution of 16 bits and is transmitted, electrically isolated, to the higher-level automation device.
The KL3182 analog input terminal processes signals in the range of -2 to +2 V. The voltage is digitized to a resolution of 16 bits and is transmitted, electrically isolated, to the higher-level automation device.
The KL3311 analog input terminal allows thermocouples to be connected directly. The Bus Terminal’s circuitry can operate thermocouple sensors using the 2-wire technique.