he 2-channel analog input terminal EL3602-0002 is a variant of the EL3602 for measurements in the range ±200 mV. The voltage is digitized to a resolution of 24 bits, and is transmitted, electrically isolated, to the higher-level automation device.
The EL3602-0010 analog input terminal handles signals in the range between -75…+75 mV. The voltage is digitized to a resolution of 24 bits, and is transmitted, electrically isolated, to the higher-level automation device.
The EL3602-0020 analog input terminal handles signals in the ranges ±10 V, ±5 V, ±2.5 V and ±1.25 V. The voltage is digitized to a resolution of 24 bits, and is transmitted, electrically isolated, to the higher-level automation device.
The EL6001 serial interface enables the connection of devices with RS232 interface The device connected to the EL6001 EtherCAT Terminal communicates with the automation device via the coupler. The active communication channel operates independently of the higher-level bus system in full duplex mode at up to 115.2 kbaud. The RS232 interface guarantees high immunity to interference through electrically isolated signals.
The EL6002 serial interface enables the connection of devices with two RS232 interfaces. The devices connected to the EL6002 EtherCAT Terminal communicate with the automation device via the Coupler.
The EL6021 serial interface enables the connection of devices with RS422 or RS485 interface. These devices communicate with the automation device via the coupler.
The EL6021-0021 serial interface enables the connection of devices with RS422 or RS485 interface. These devices communicate with the automation device via the coupler.
The EL6022 serial interface enables the connection of devices with two RS422/RS485 interfaces. The devices connected to the EL6022 EtherCAT Terminal communicate with the automation device via the Coupler.
TwinCAT 3.1 offers an option to manage TwinCAT software licenses via the EtherCAT Terminal EL6070. The EL6070 embodies the hardware license key in the modular EtherCAT I/O system. Data transfer takes place via EtherCAT.
Note that the EL6070 and EL6070-0033 are two different devices in terms of EtherCAT and are therefore not interchangeable in the EtherCAT I/O configuration.
The EL6080 EtherCAT memory terminal has 128 kB of non-volatile memory (NOVRAM). The terminal can be used to store and read out parameters and recipes. Part of the memory can also be used for the cyclic storage of machine data such as operating hour meters or production numbers.
The EL6601 Ethernet switch port terminal is used for the decentralized connection of Ethernet devices to the EtherCAT Terminal network. The EtherCAT system relays the Ethernet communication of the connected devices fully transparent and collision-free.