The stepper motor module is used to control up to 2 stepper motors with a nominal voltage of 24 to 38.5 VDC ±25% at a motor current up to 3 A (5 A peak).In addition, this module has 6 digital inputs that can be used as limit switches or encoder inputs.
This motor bridge module is used to control 2 DC motors with a nominal voltage of 24 to 38.5 VDC ±25% at a nominal current up to 3 A. The module can be reconfigured and used in current controller mode for controlling inductive loads.
This module is a multifunctional counter module. It can be connected to two SSI encoders, two ABR encoders, four AB encoders or eight event counters. Four outputs are available for pulse width modulation. The functions can also be mixed.
The bus receiver is used to connect the X20 System to the X2X Link. The module is equipped with a feed for the X2X Link as well as the internal I/O supply.
The 2-port EtherCAT junction enables configuration of EtherCAT star topologies. A modular EtherCAT star can be realized by using several EP1122-0001 units in a station. Individual devices or complete EtherCAT strands can be connected at the junction ports. The EtherCAT junctions are connected via M8 sockets with direct display of link and activity status. The Run LED indicates the status of the EP1122-0001.
ACOPOS servo drive, 3x 400-480 V, 34 A, 16 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
The EP2338-0001 EtherCAT Box has eight digital channels that can each be operated as inputs or outputs. It is not necessary to configure whether a channel (pin 4 of the M8) is to be used as input or output; the input circuit is permanently connected internally to the output driver, so that a set output is automatically displayed in the input process image.