The KL1052 digital input terminal acquires the binary 24 V DC control signals from the process level and transmits them, in an electrically isolated form, to the higher-level automation unit. The Bus Terminal contains two channels that indicate their signal state by means of light emitting diodes.
The job of the KL3051 analog input terminal is to supply power to measuring transducers located in the field and to transmit analog measurement signals with electrical isolation to the automation device.
The job of the KL3052 analog input terminal is to supply power to measuring transducers located in the field and to transmit analog measurement signals with electrical isolation to the automation device.
The job of the KL3054 analog input terminal is to transmit analog measurement signals with electrical isolation to the automation device. The input electronics is independent of the supply voltage of the power contacts.
The bidirectional KL5051 SSI interface terminal is used to connect digital servo drives. The interface consists of two logical channels. The first channel is used to position the drive
The KL6051 serial interface terminal makes it possible to exchange data between different fieldbus systems. Full duplex data exchange is possible, independently of the higher-level fieldbus. Under the terminal’s default setting, 32 inputs and 32 outputs are transferred between the fieldbus systems.
The KL9050 coupler terminal replaces the Bus Coupler on a Bus Terminal block. The KL9050 is the counterpart to the KL9020. The S(F)TP cable (shielded twisted pair) is plugged into the upper socket, providing the logical connection to the Bus Coupler.
The KL9110 power feed terminal makes it possible to set up various potential groups with the standard voltage of 24 V DC. In order to monitor the supply voltage, the terminal with diagnostics reports the status of the power feed terminal to the Bus Coupler through two input bits. It is thus possible for the controller to check the distributed peripheral voltage over the fieldbus.
The KL9184 potential distribution terminal provides the potential of the 24 V DC contact at 8 terminal points and the potential of the 0 V contact at 8 terminal points. The conductors can be connected without tools in the case of solid wires using a direct plug-in technique.
The potential distribution terminal KL9186 provides eight terminal points with a potential and enables the voltage to be picked up without further bus terminal blocks or wiring.
The potential distribution terminal KL9187 provides eight terminal points with a potential and enables the voltage to be picked up without further bus terminal blocks or wiring.