Special features:input specification type 1/3 low delay due to 0.2 ms input filter +24 V DC and 0 V DC sensor supply connections tool-free connection by direct plug-in technology for solid wire conductors increased packing density with 16 connection points in the housing of a 12 mm terminal block
Special features: input specification type 1/3 low delay due to 0.2 ms input filter tool-free connection by direct plug-in technology for solid wire conductors space-saving use in the control cabinet direct connection of multi-channel sensors in 1-wire connection technology in the smallest space ,increased packing density with 16 connection points in the housing of a 12 mm terminal block
Special features: compact design through the combination of inputs and outputs in one terminal no bouncing due to mechanical switches thanks to 3 ms input filter short-circuit proof outputs protected against reverse polarity with output current up to 0.5 A tool-free connection by direct plug-in technology for solid wire conductors increased packing density with 16 connection points in the housing of a 12 mm terminal block
Special features: input specification type 1/3 no bouncing due to mechanical switches thanks to 3 ms input filter direct connection of connectors with insulation displacement contacts
Special features: input specification type 1/3 low delay due to 0.2 ms input filter direct connection of connectors with insulation displacement contacts
Special features: ground switching no bouncing due to mechanical switches thanks to 3 ms input filter tool-free connection by direct plug-in technology for solid wire conductors space-saving use in the control cabinet direct connection of multi-channel sensors in 1-wire connection technology in the smallest space
The KL9110 power feed terminal makes it possible to set up various potential groups with the standard voltage of 24 V DC. In order to monitor the supply voltage, the terminal with diagnostics reports the status of the power feed terminal to the Bus Coupler through two input bits. It is thus possible for the controller to check the distributed peripheral voltage over the fieldbus.
The KL9210 power feed terminal makes it possible to set up various potential groups with the standard voltage of 24 V DC. In order to monitor the supply voltage, the terminal with diagnostics reports the status of the power feed terminal to the Bus Coupler through two input bits. It is thus possible for the controller to check the distributed peripheral voltage over the fieldbus.
The KL9505 power supply terminal generates an output voltage of 5 V DC from the (24 V DC) input voltage, which can be accessed at the terminal. The following Bus Terminals are also supplied with this voltage via the power contacts. The power LEDs indicate the terminal’s operating state. The input voltage and the output voltage U0 are not electrically isolated.