The KL1302 digital input terminal acquires the binary 24 V DC control signals from the process level and transmits them, in an electrically isolated form, to the higher-level automation unit. The Bus Terminal has two channels, whose signal state is displayed by light emitting diodes.
The KL1304 digital input terminal acquires the binary 24 V DC control signals from the process level and transmits them, in an electrically isolated form, to the higher-level automation unit. The Bus Terminal has four channels, whose signal state is displayed by light emitting diodes.
The KL1314 digital input terminal acquires the binary 24 V DC control signals from the process level and transmits them, in an electrically isolated form, to the higher-level automation unit. The Bus Terminal has four channels, whose signal state is displayed by light emitting diodes.
The KL1352 digital input terminal analyzes the input signal of NAMUR sensors according to IEC 60947-5-6. The Bus Terminal has two channels. In addition to the display of the signal state from the sensor, short circuit or open circuit is also detected. The LEDs display the signal states or any error states.
The digital KL1362 input terminal analyzes the input signals of break-in sensors with the aid of a current loop. It enables safe monitoring of alarm contacts with fixed resistance ratio. In addition to the display of the switching state from the sensor, short circuit or open circuit is also detected. The LEDs display the signal states or any error states.
The KL1414 digital input terminal acquires the binary 24 V DC control signals from the process level and transmits them, in an electrically isolated form, to the higher-level automation unit. The Bus Terminal contains four channels that indicate its signal state by means of light emitting diodes.
The KL1418 digital input terminal acquires the binary 24 V DC control signals from the process level and transmits them, in an electrically isolated form, to the higher-level automation unit.
Special features: ground switching low delay due to 0.2 ms input filter direct connection of multi-channel sensors in 1-wire connection technology in the smallest space
The KL1512 Bus Terminal is a 2-channel up or down counter and transports the counter value electrically isolated to the higher-level automation device.
Special features:input specification type 1/3 no bouncing due to mechanical switches thanks to 3 ms input filter +24 V DC and 0 V DC sensor supply connections tool-free connection by direct plug-in technology for solid wire conductors increased packing density with 16 connection points in the housing of a 12 mm terminal block
Special features:input specification type 1/3 no bouncing due to mechanical switches thanks to 3 ms input filter tool-free connection by direct plug-in technology for solid wire conductors space-saving use in the control cabinet direct connection of multi-channel sensors in 1-wire connection technology in the smallest space increased packing density with 16 connection points in the housing of a 12 mm terminal block