Cycle times from 200 µs are possible. PROFIBUS DP, PROFIBUS DP-V1, PROFIBUS DP-V2 master and slave up to 12 Mbit/s powerful parameter and diagnostics interfaces The error management for each bus user is freely configurable. It is possible to read the bus configuration and automatically assign the “GSD” files.
The Terminal enables within an EtherCAT Terminal network the integration of any CANopen devices and can either be master (EL6751) or slave (EL6751-0010).
The Terminal enables within an EtherCAT Terminal network the integration of any DeviceNet devices and can either be master (EL6752) or slave (EL6752-0010).
The EL9515 power supply terminal takes the input voltage (24 V DC) and uses it to generate an output voltage of 15 V DC at 0.5 A, which can be tapped at the terminal.
The BK2000 Bus Coupler connects the Lightbus system to the electronic terminal blocks, which can be expanded in modular fashion. One unit consists of one Bus Coupler, any number of up to 64 terminals and one end terminal.
The BK5200 Bus Coupler connects the DeviceNet bus system to the electronic terminal blocks, which can be extended in modular fashion. One unit consists of one Bus Coupler, any number of up to 64 terminals and one end terminal.
Special features:input specification type 1/3 no bouncing due to mechanical switches thanks to 3 ms input filter tool-free connection by direct plug-in technology for solid wire conductors space-saving use in the control cabinet direct connection of multi-channel sensors in 1-wire connection technology in the smallest space increased packing density with 16 connection points in the housing of a 12 mm terminal block
Special features:input specification type 1/3 low delay due to 0.2 ms input filter +24 V DC and 0 V DC sensor supply connections tool-free connection by direct plug-in technology for solid wire conductors increased packing density with 16 connection points in the housing of a 12 mm terminal block
Special features: ground switching no bouncing due to mechanical switches thanks to 3 ms input filter tool-free connection by direct plug-in technology for solid wire conductors space-saving use in the control cabinet direct connection of multi-channel sensors in 1-wire connection technology in the smallest space
he KL3142 analog input terminal handles signals in the range between 0 and 20 mA. The current is digitized to a resolution of 16 bits, and is transmitted, in an electrically isolated form, to the higher-level automation device.
The KL3152 analog input terminal handles signals in the range between 4 and 20 mA. The current is digitized to a resolution of 16 bits, and is transmitted, in an electrically isolated form, to the higher-level automation device.