The BK1150 EtherCAT Coupler is the link between the EtherCAT protocol at fieldbus level and the Bus Terminals. The coupler converts the passing telegrams from Ethernet 100BASE-TX to the internal, fieldbus-independent terminal bus.
The Compact Bus Coupler BK7150 connects the CC-Link system to the electronic terminal blocks, which can be extended in modular fashion. One unit consists of the Bus Coupler, any number of up to 64 terminals and one end terminal. The K-bus extension technology allows the connection of up to 255 spatially distributed Bus Terminals to one Bus Coupler.
Special features: suitable for fast counting tasks with counting frequencies up to 100 kHz an up counter and a down counter, or two separate up or down counters
E-mail:sales1@swanautomation.com (Click) ProSoft Technology MVI69E-MBTCP Modbus TCP/IP Enhanced Communication Module for Allen-Bradley CompactLogix or MicroLogix Platform, 1 x 10/100MBps Ethernet Port for diagnostic and application data, can support both Client and Server connectivity to interface with a variety of devices using the Modbus Protocol
SIMATIC S7-1500, analog output module AQ 4xU/I HF, 16-bit resolution accuracy 0.1%, 4 channels in groups of 1, common mode voltage: 30 V AC/60 V DC, diagnostics; substitute value, isochronous mode; the module supports the safety-oriented shutdown of load groups up to SIL2 according to EN IEC 62061
SIMATIC S7-1500 analog input module AI 8xU/I HF, up to 24 bit resolution, accuracy 0.1%, 8 channels in groups of 1; common mode voltage: 30 V AC/60 V DC, Diagnostics; Hardware interrupts Measured values scalable, measuring range adjustment, Calibrate in RUN; Delivery including infeed element, shield bracket and shield terminal: Front connector (screw terminals or push-in) to be ordered separately
Allen Bradley 20AD040A0AYNANC0 PowerFlex 70 AC Drive, 480V AC, 3PH, 40A, 30HP Normal Duty, 25HP Heavy Duty, Panel Mount - IP20 / NEMA Type 1, with Conformal Coating, No HIM (Blank Plate), Brake IGBT Installed, Without Drive Mounted Brake Resistor, Second Environment Filter per CE EMC directive (89/336/EEC), No Communication Module, Enhanced Control , No Feedback
Allen-Bradley 1788-CN2DN ControlNet-to-DeviceNet (CN2DN) linking device. The 1788-CN2DN connects a ControlNet network to a DeviceNet network. The DeviceNet network typically consists of multiple devices, such as RediStation’s, photoeyes, etc. The ControlNet network consists of controllers, such as Logix or PLC-5 processors, HMIs, drives, I/O devices, etc
Allen-Bradley 2711P-T12C4A8 PanelView Plus 6 1250 Color Terminal 12.1 inch, Touch, Standard Communications (Ethernet & RS-232), 512MB Flash, 512MB RAM, AC Power
330150-02-12-10-02-00 Bently probes, Bently sensors, Bently power modules, Bently cables, and Bently accelerometers from the United States have a complete range of products