The PROFIBUS master terminal EL6731 supports the PROFIBUS protocol with all its features. Within an EtherCAT Terminal network, it enables the integration of any PROFIBUS devices.
The Interbus slave terminal facilitates data exchange between EtherCAT and Interbus. For both bus systems the terminal “mirrors” up to 32 word input and 32 word output to the respective other system.
The EL6851 EtherCAT Terminal is a DMX master terminal and enables connection of up to 32 devices without repeater. The DMX master terminal can send up to 512 bytes of data (this can be set via the terminal). At 250 kbit/s a maximum data rate of 44 kHz is therefore possible. The RS485 interface in the EL6851 is electrically isolated and guarantees high interference immunity.
The EL9210 potential feed terminal with fuse and diagnostics enables the setup of different potential groups with a fused standard voltage of 24 V DC. The supply voltage is taken up via the front terminal contacts, fused and passed through to the adjacent terminals via the internal power contacts. The fuse is a 6.3 A fuse, which can be replaced at the front.
The EL9512 power supply unit terminal generates an output voltage of 12 V DC from the 24 V DC input voltage. The output voltage can be accessed at the terminal.
The EL9550 system terminal contains an overvoltage filter for the 24 V field and system supply. The filter protects the EtherCAT Terminal from line-bound surge voltages that can occur due to high-energy, dynamic disturbances such as switching overvoltages at inductive consumers or indirect lightning strikes at the supply lines.
The EL9080 separation terminal is used for the separation and marking of different potential groups (e.g., 230 V AC/24 V DC). It is inserted between two potential groups, and indicates the separation through an orange colored cover. The E-bus is passed through in the usual way to the adjacent terminal.
The EL9186 potential distribution terminal provides 8 terminal points with the 24 V potential at the front on the terminal contacts. The 24 V power contact is connected to the front-side terminal contacts and is passed through to the adjacent terminal. The 0 V power contact is not connected to the front-side terminal contacts and is passed through to the adjacent terminal. With the EL9186, the use of additional terminal blocks on the terminal strip can be reduced.
The EL9187 potential distribution terminal provides 8 terminal points with the 0 V potential at the front on the terminal contacts. The 0 V power contact is connected to the front-side terminal contacts and is passed through to the adjacent terminal.
The EL9188 potential distribution terminal provides 16 terminal points with the 24 V potential at the front on the terminal contacts. The 24 V power contact is connected to the front-side terminal contacts and is passed through to the adjacent terminal.
The EL9189 potential distribution terminal provides 16 terminal points with the 0 V potential at the front on the terminal contacts. The 0 V power contact is connected to the front-side terminal contacts and is passed through to the adjacent terminal.