The KL3132 analog input terminal processes signals in the range of -10 to +10 V. The voltage is digitized to a resolution of 16 bits and is transmitted, electrically isolated, to the higher-level automation device.
he KL3142 analog input terminal handles signals in the range between 0 and 20 mA. The current is digitized to a resolution of 16 bits, and is transmitted, in an electrically isolated form, to the higher-level automation device.
The KL3152 analog input terminal handles signals in the range between 4 and 20 mA. The current is digitized to a resolution of 16 bits, and is transmitted, in an electrically isolated form, to the higher-level automation device.
The KL3201 analog input terminal allows resistance sensors to be connected directly. The Bus Terminal’s circuitry can operate the sensors using 2-wire or 3-wire connection techniques.
The KL3222 analog input terminal allows resistance sensors to be connected directly. Linearization over the full temperature range is realized with the aid of a microprocessor. The temperature range can be selected freely.
The KL3444 analog input terminal processes signals in the range between 0 and 20 mA. The current is digitized to a resolution of 12 bits and is transmitted, in an electrically isolated form, to the higher-level automation device.
The KL3444 analog input terminal processes signals in the range between 0 and 20 mA. The current is digitized to a resolution of 12 bits and is transmitted, in an electrically isolated form, to the higher-level automation device.
The analog input terminal KL3464 processes signals in the range between 0 and 10 V. The voltage is digitized to a resolution of 12 bits and is transmitted, electrically isolated, to the higher-level automation device.
The KL4001 analog output terminal generates signals in the range from 0 to 10 V. The voltage is supplied to the process level with a resolution of 12 bits and is electrically isolated. The output channels of the Bus Terminal have a common ground potential.
The KL4002 analog output terminal generates signals in the range from 0 to 10 V. The voltage is supplied to the process level with a resolution of 12 bits and is electrically isolated.
The KL4011 analog output terminal generates analog output signals in the range from 0 to 20 mA. The power is supplied to the process level with a resolution of 12 bits and is electrically isolated.
The KL4012 analog output terminal generates analog output signals in the range from 0 to 20 mA. The power is supplied to the process level with a resolution of 12 bits and is electrically isolated.